Littelfuse Current Sensors – Industrial

Results: 70
Select Image Part # Mfr. Description Datasheet Availability Pricing (EUR) Filter the results in the table by unit price based on your quantity. Qty. RoHS ECAD Model Current Rating Sensor Type Response Time Accuracy Frequency Range
Littelfuse Current Sensors – Industrial 230VAC ISOLATED SPDT CURRENT SENSOR 1In Stock
Min.: 1
Mult.: 1

20 A Closed Loop 6 s 45 Hz to 500 Hz
Littelfuse Current Sensors – Industrial 120VAC ISOLATED SPDT CURRENT SENSOR 7In Stock
Min.: 1
Mult.: 1

5 A Closed Loop 1 s 45 Hz to 500 Hz
Littelfuse Current Sensors – Industrial 300A Analog CuSn6, Sn plating 97In Stock
Min.: 1
Mult.: 1

100 A to 300 A Open Loop 20 us
Littelfuse Current Sensors – Industrial 800A Analog CuSn6, Sn plating 100In Stock
Min.: 1
Mult.: 1

100 A to 800 A Open Loop 20 us
Littelfuse Current Sensors – Industrial 1100A Analog CuSn6, Sn plating 95In Stock
Min.: 1
Mult.: 1

100 A to 1100 A Open Loop 20 us
Littelfuse Current Sensors – Industrial 120VAC ISOLATED SPDT CURRENT SENSOR 21In Stock
8Expected 5/7/2026
Min.: 1
Mult.: 1

5 A Closed Loop 1 s 45 Hz to 500 Hz
Littelfuse Current Sensors – Industrial 120VAC ISOLATED SPDT CURRENT SENSOR 1In Stock
Min.: 1
Mult.: 1

20 A Closed Loop 2 s 45 Hz to 500 Hz
Littelfuse Current Sensors – Industrial 120VAC ISOLATED SPDT CURRENT SENSOR 2In Stock
Min.: 1
Mult.: 1

20 A Closed Loop 2 s 45 Hz to 500 Hz
Littelfuse Current Sensors – Industrial PANELMOUNTLED 48In Stock
Min.: 1
Mult.: 1

Littelfuse Current Sensors – Industrial 120VAC ISOLATED SPDT CURRENT SENSOR 5In Stock
Min.: 1
Mult.: 1

20 A Closed Loop 1 s 45 Hz to 500 Hz
Littelfuse Current Sensors – Industrial Sensor for Battery Management
99On Order
Min.: 1
Mult.: 1
55 mA Open Loop
Littelfuse Current Sensors – Industrial Sensor for Pyro Triggering
100On Order
Min.: 1
Mult.: 1
35 mA Open Loop 80 ms
Littelfuse Current Sensors – Industrial 120VAC ISOLATED SPDT CURRENT SENSOR
9Expected 3/23/2026
Min.: 1
Mult.: 1

10 A Closed Loop 0.5 s to 50 s 45 Hz to 500 Hz
Littelfuse Current Sensors – Industrial Sensor for Motor Control +/-600 A
100On Order
Min.: 1
Mult.: 1
13 mA Open Loop 6 us
Littelfuse Current Sensors – Industrial Sensor for Motor Control +/-700 A
100On Order
Min.: 1
Mult.: 1
13 mA Open Loop 6 us
Littelfuse Current Sensors – Industrial Sensor for Motor Control +/-800 A
100On Order
Min.: 1
Mult.: 1
13 mA Open Loop 6 us
Littelfuse Current Sensors – Industrial Sensor for Motor Control +/-900 A
100On Order
Min.: 1
Mult.: 1
13 mA Open Loop 6 us
Littelfuse Current Sensors – Industrial CALIBRATEDCURRENTSEN SOR
5Expected 4/14/2026
Min.: 1
Mult.: 1

50 A 20 Hz to 100 Hz
Littelfuse Current Sensors – Industrial WINDOWCURRENTSENSOR
5Expected 3/18/2026
Min.: 1
Mult.: 1

20 A Closed Loop 6 s 45 Hz to 500 Hz
Littelfuse Current Sensors – Industrial 120V 0.5-5A 0.150-7s CURRENT SENSOR 2s Non-Stocked Lead-Time 11 Weeks
Min.: 1
Mult.: 1

50 A Open Loop 300 ms +/- 0.25 % 20 Hz, 30 Hz
Littelfuse Current Sensors – Industrial 120VAC ISOLATED SPDT CURRENT SENSOR Non-Stocked Lead-Time 11 Weeks
Min.: 1
Mult.: 1

5 A Closed Loop 0 s 45 Hz to 500 Hz
Littelfuse Current Sensors – Industrial 120VAC ISOLATED SPDT CURRENT SENSOR Non-Stocked Lead-Time 11 Weeks
Min.: 1
Mult.: 1

20 A Closed Loop 2 s 45 Hz to 500 Hz
Littelfuse Current Sensors – Industrial 120VAC ISOLATED SPDT CURRENT SENSOR Non-Stocked Lead-Time 11 Weeks
Min.: 1
Mult.: 1

20 A Closed Loop 6 s 45 Hz to 500 Hz
Littelfuse Current Sensors – Industrial 120VAC ISOLATED SPDT CURRENT SENSOR Non-Stocked Lead-Time 11 Weeks
Min.: 1
Mult.: 1

50 A Closed Loop 1 s 45 Hz to 500 Hz
Littelfuse Current Sensors – Industrial 120VAC ISOLATED SPDT CURRENT SENSOR Non-Stocked Lead-Time 11 Weeks
Min.: 1
Mult.: 1

50 A Closed Loop 6 s 45 Hz to 500 Hz