Solicon DRC3 Solid State Contactors

Crydom's Solicon DRC3 Solid State Contactors are intended for frequently switching on and off three-phase loads up to 5HP, 600VAC 7.6A. They are available in two contactor options, DRC3P and DRC3R (reversing). The Solicon Contactor DRC3P is available in either instantaneous turn-on (for motor control) or zero voltage turn-on (for resistive loads). DRC3P is also available in either 2 or 3 controlled leg versions. The 2 legs control version is particularly suitable for motor control circuits where the neutral conductor is not utilized.

Results: 134
Select Image Part # Mfr. Description Datasheet Availability Pricing (EUR) Filter the results in the table by unit price based on your quantity. Qty. RoHS ECAD Model Mounting Style Load Current Rating Load Voltage Rating Control Voltage Range Input Current Minimum Operating Temperature Maximum Operating Temperature Length Width Height Packaging Series
Crydom Contactors - Solid State SSR Contactor, 3-Phase, DIN Rail Mount, 480VAC/7.6A, 48VAC/DC In, 2NO, RN, 3L Non-Stocked Lead-Time 18 Weeks
Min.: 10
Mult.: 10

DIN Rail Mount Each DRC3
Crydom Contactors - Solid State SSR Contactor, 3-Phase, DIN Rail Mount, 480VAC/4.8A, 48VAC/DC In, 2NO, RN, 2L Non-Stocked Lead-Time 18 Weeks
Min.: 10
Mult.: 10

DIN Rail Mount Each DRC3
Crydom Contactors - Solid State 3P 480V 7.6A 24V/DC NO AUX ZC 2L Non-Stocked Lead-Time 16 Weeks
Min.: 10
Mult.: 10

DIN Rail Mount 7.6 A 48 VAC to 510 VAC 18 VAC to 30 VAC, 18 VDC to 30 VDC 12.5 mA to 32 mA - 30 C + 80 C 96.02 mm 45.31 mm 86.71 mm Each DRC3
Crydom Contactors - Solid State 3P 480V 7.6A 24V/DC 1NO+1NC RN 2L Non-Stocked Lead-Time 14 Weeks
Min.: 1
Mult.: 1

DIN Rail Mount 7.6 A 48 VAC to 510 VAC 18 VAC to 30 VAC, 18 VDC to 30 VDC 12.5 mA to 32 mA - 30 C + 80 C 96.02 mm 45.31 mm 86.71 mm Each DRC3
Crydom Contactors - Solid State 3P 480V 7.6A 24V/DC 2NO RN 3L Non-Stocked Lead-Time 14 Weeks
Min.: 10
Mult.: 10

DIN Rail Mount 4.8 A 48 VAC to 510 VAC 18 VAC to 30 VAC, 18 VDC to 30 VDC 12.5 mA to 32 mA - 30 C + 80 C 96.02 mm 45.31 mm 86.71 mm Each DRC3
Crydom Contactors - Solid State 7.6A 480VAC 3Phs 1NO+1NC EMR, ZC, 2L Non-Stocked Lead-Time 18 Weeks
Min.: 10
Mult.: 10

DIN Rail Mount 7.6 A 480 VAC 18 VAC to 30 VAC, 18 VDC to 30 VDC 32 mA - 20 C + 60 C Each DRC3
Crydom Contactors - Solid State 7.6A 480VAC 3Phs 2NO EMR, ZC, 3L Non-Stocked Lead-Time 18 Weeks
Min.: 10
Mult.: 10

DIN Rail Mount 4.8 A 480 VAC 18 VAC to 30 VAC, 18 VDC to 30 VDC 32 mA - 20 C + 60 C Each DRC3
Crydom Contactors - Solid State 4.8A 480VAC 3Phs 2NO EMR, ZC, 2L Non-Stocked Lead-Time 18 Weeks
Min.: 10
Mult.: 10

DIN Rail Mount 7.6 A 480 VAC 18 VAC to 30 VAC, 18 VDC to 30 VDC 32 mA - 20 C + 60 C Each DRC3
Crydom Contactors - Solid State 7.6A 480VAC 3Phs 2NO EMR, RN, 3L Non-Stocked Lead-Time 18 Weeks
Min.: 10
Mult.: 10

DIN Rail Mount 4.8 A 480 VAC 18 VAC to 30 VAC, 18 VDC to 30 VDC 32 mA - 20 C + 60 C Each DRC3
Crydom Contactors - Solid State 4.8A 480VAC 3Phs 2NO EMR, RN, 2L Non-Stocked Lead-Time 18 Weeks
Min.: 10
Mult.: 10

DIN Rail Mount 7.6 A 480 VAC 18 VAC to 30 VAC, 18 VDC to 30 VDC 32 mA - 20 C + 60 C Each DRC3
Crydom Contactors - Solid State SSR Contactor, 3-Phase, DIN Rail Mount, 600VAC/4.8A, 230VAC In, NO Aux, ZC, 3L Non-Stocked Lead-Time 18 Weeks
Min.: 10
Mult.: 10

DIN Rail Mount Each DRC3
Crydom Contactors - Solid State SSR Contactor, 3-Phase, DIN Rail Mount, 600VAC/7.6A, 230VAC In, NO Aux, ZC, 2L Non-Stocked Lead-Time 18 Weeks
Min.: 10
Mult.: 10

DIN Rail Mount Each DRC3
Crydom Contactors - Solid State SSR Contactor, 3-Phase, DIN Rail Mount, 600VAC/4.8A, 230VAC In, NO Aux, RN, 3L Non-Stocked Lead-Time 18 Weeks
Min.: 10
Mult.: 10

DIN Rail Mount Each DRC3
Crydom Contactors - Solid State SSR Contactor, 3-Phase, DIN Rail Mount, 600VAC/7.6A, 230VAC In, NO Aux, RN, 2L Non-Stocked Lead-Time 18 Weeks
Min.: 10
Mult.: 10

DIN Rail Mount Each DRC3
Crydom Contactors - Solid State SSR Contactor, 3-Phase, DIN Rail Mount, 600VAC/4.8A, 230VAC In, 1NO+1NC, ZC, 3L Non-Stocked Lead-Time 18 Weeks
Min.: 10
Mult.: 10

DIN Rail Mount Each DRC3
Crydom Contactors - Solid State SSR Contactor, 3-Phase, DIN Rail Mount, 600VAC/7.6A, 230VAC In, 1NO+1NC, ZC, 2L Non-Stocked Lead-Time 18 Weeks
Min.: 10
Mult.: 10

DIN Rail Mount Each DRC3
Crydom Contactors - Solid State SSR Contactor, 3-Phase, DIN Rail Mount, 600VAC/4.8A, 230VAC In, 1NO+1NC, RN, 3L Non-Stocked Lead-Time 18 Weeks
Min.: 10
Mult.: 10

DIN Rail Mount Each DRC3
Crydom Contactors - Solid State SSR Contactor, 3-Phase, DIN Rail Mount, 600VAC/7.6A, 230VAC In, 1NO+1NC, RN, 2L Non-Stocked Lead-Time 18 Weeks
Min.: 10
Mult.: 10

DIN Rail Mount Each DRC3
Crydom Contactors - Solid State SSR Contactor, 3-Phase, DIN Rail Mount, 600VAC/4.8A, 230VAC In, 2NO, ZC, 3L Non-Stocked Lead-Time 18 Weeks
Min.: 10
Mult.: 10

DIN Rail Mount Each DRC3
Crydom Contactors - Solid State SSR Contactor, 3-Phase, DIN Rail Mount, 600VAC/7.6A, 230VAC In, 2NO, ZC, 2L Non-Stocked Lead-Time 18 Weeks
Min.: 10
Mult.: 10

DIN Rail Mount Each DRC3
Crydom Contactors - Solid State SSR Contactor, 3-Phase, DIN Rail Mount, 600VAC/4.8A, 230VAC In, 2NO, RN, 3L Non-Stocked Lead-Time 18 Weeks
Min.: 10
Mult.: 10

DIN Rail Mount Each DRC3
Crydom Contactors - Solid State SSR Contactor, 3-Phase, DIN Rail Mount, 600VAC/7.6A, 230VAC In, 2NO, RN, 2L Non-Stocked Lead-Time 18 Weeks
Min.: 10
Mult.: 10

DIN Rail Mount Each DRC3
Crydom Contactors - Solid State SSR Contactor, 3-Phase, DIN Rail Mount, 600VAC/4.8A, 120VAC In, NO Aux, ZC, 3L Non-Stocked Lead-Time 18 Weeks
Min.: 10
Mult.: 10

DIN Rail Mount Each DRC3
Crydom Contactors - Solid State SSR Contactor, 3-Phase, DIN Rail Mount, 600VAC/7.6A, 120VAC In, NO Aux, ZC, 2L Non-Stocked Lead-Time 18 Weeks
Min.: 10
Mult.: 10

DIN Rail Mount Each DRC3
Crydom Contactors - Solid State SSR Contactor, 3-Phase, DIN Rail Mount, 600VAC/4.8A, 120VAC In, NO Aux, RN, 3L Non-Stocked Lead-Time 18 Weeks
Min.: 10
Mult.: 10

DIN Rail Mount Each DRC3