LAH Board Mount Current Sensors

LEM LAH Board Mount Current Sensors are designed for precise measurement of DC, AC, and pulse currents, with nominal values ranging from 8A to 125A RMS. These closed-loop Hall effect sensors come in a compact design with an integrated primary conductor. The PCB mounting capability for both primary and secondary circuits enhances the ease of integration of these transducers. The LAH current sensors offer galvanic isolation, excellent accuracy, and fast response time, which makes them an ideal choice for industrial applications.

Results: 13
Select Image Part # Mfr. Description Datasheet Availability Pricing (EUR) Filter the results in the table by unit price based on your quantity. Qty. RoHS ECAD Model Current Rating Sensor Type Response Time Accuracy Frequency Range Operating Supply Voltage Output Type
LEM Board Mount Current Sensors Current Transducer LAH 50-P For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. 1.455In Stock
Min.: 1
Mult.: 1

50 A Closed Loop 500 ns 0.25 % 200 kHz 12 V to 15 V Digital, Analog
LEM Board Mount Current Sensors Current Transducer LAH 125-P For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. 178In Stock
Min.: 1
Mult.: 1

125 A Closed Loop 1 us 0.41 % 100 kHz 12 V to 15 V Digital, Analog
LEM Board Mount Current Sensors Current Transducer LAH 25-NP For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. 547In Stock
300Expected 4/10/2026
Min.: 1
Mult.: 1

25 A Closed Loop 500 ns 0.3 % 200 kHz 12 V to 15 V Digital, Analog
LEM Board Mount Current Sensors Current Transducer LAH 100-P For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.
2.095On Order
Min.: 1
Mult.: 1

100 A Closed Loop 500 ns 0.25 % 200 kHz 12 V to 15 V Digital, Analog
LEM Board Mount Current Sensors Non-Stocked Lead-Time 10 Weeks
Min.: 300
Mult.: 300
100 A Closed Loop 200 kHz 12 V to 15 V Digital, Analog
LEM Board Mount Current Sensors Non-Stocked Lead-Time 10 Weeks
Min.: 300
Mult.: 300
100 A Closed Loop 200 kHz 12 V to 15 V Digital, Analog
LEM Board Mount Current Sensors Non-Stocked Lead-Time 10 Weeks
Min.: 300
Mult.: 300
25 A Closed Loop 0.3 % 200 kHz 12 V to 15 V Digital, Analog
LEM Board Mount Current Sensors Non-Stocked Lead-Time 10 Weeks
Min.: 300
Mult.: 300
25 A Closed Loop 0.3 % 200 kHz 12 V to 15 V Digital, Analog
LEM Board Mount Current Sensors Non-Stocked Lead-Time 10 Weeks
Min.: 300
Mult.: 300
25 A Closed Loop 0.3 % 200 kHz 12 V to 15 V Digital, Analog
LEM Board Mount Current Sensors Non-Stocked Lead-Time 10 Weeks
Min.: 300
Mult.: 300
25 A Closed Loop 0.3 % 200 kHz 12 V to 15 V Digital, Analog
LEM Board Mount Current Sensors Non-Stocked Lead-Time 10 Weeks
Min.: 300
Mult.: 300
50 A Closed Loop 500 ns 0.25 % 200 kHz 12 V to 15 V Digital, Analog
LEM Board Mount Current Sensors Non-Stocked Lead-Time 10 Weeks
Min.: 300
Mult.: 300
50 A Closed Loop 500 ns 0.25 % 200 kHz 12 V to 15 V Digital, Analog
LEM Board Mount Current Sensors Non-Stocked Lead-Time 14 Weeks
Min.: 300
Mult.: 300
25 A Closed Loop 0.3 % 200 kHz 12 V to 15 V Digital, Analog