UM (V-EA) Circuit Breakers

Altech UM (V-EA) Circuit Breakers are UL 508-listed manual motor controllers that are suitable as motor disconnects. These DIN-rail-mounted circuit breakers are thermal magnetic and have a width of 17.5mm per pole. The series features a 0.3A to 60A current rating, 277VAC voltage rating, and 10kA short circuit withstand capacity. Altech UM (V-EA) Circuit Breakers are ideal for use in AC motor starting, AC general use, AC resistance, AC discharge lamp, and AC incandescent lamp applications.

Results: 452
Select Image Part # Mfr. Description Datasheet Availability Pricing (EUR) Filter the results in the table by unit price based on your quantity. Qty. RoHS ECAD Model Series Product Type Current Rating Voltage Rating AC Voltage Rating DC Number of Poles Actuator Type Minimum Operating Temperature Maximum Operating Temperature Illuminated
Altech Circuit Breakers 10A MCB CCHAR 3 PL 480Y/277VAC UL508 36In Stock
Min.: 1
Mult.: 1

UM Circuit Breakers C-Trip 10 A 277 VAC 80 VDC 3 Pole Handle - 25 C + 55 C Non-Illuminated
Altech Circuit Breakers 6A MCB CCHARL 480Y/277VAC UL508 1In Stock
Min.: 1
Mult.: 1

UM 6 A 277 VAC 80 VDC 3 Pole Handle - 25 C + 55 C Non-Illuminated
Altech Circuit Breakers 3D1UM, 1A,CIRCUIT BREAKER 7In Stock
Min.: 1
Mult.: 1
UM Circuit Breakers D-Trip 1 A 277 VAC 80 VDC 3 Pole Handle - 25 C + 55 C Non-Illuminated
Altech Circuit Breakers 32A Z Characteristic UL 508 1 POLE 12In Stock
Min.: 1
Mult.: 1

UM 32 A 277 VAC 24 VDC 1 Pole Handle - 25 C + 55 C Non-Illuminated
Altech Circuit Breakers 3.5A MCB GCHAR 1pl 277VAC UL508 3In Stock
Min.: 1
Mult.: 1

UM Circuit Breakers G-Trip 3.5 A 277 VAC 42 VDC 1 Pole Handle - 25 C + 55 C Non-Illuminated
Altech Circuit Breakers 10A MCB B Char 1pl 277VAC UL508 4In Stock
Min.: 1
Mult.: 1

UM Circuit Breakers B-Trip 10 A 277 VAC 42 VDC 1 Pole Handle - 25 C + 55 C Non-Illuminated
Altech Circuit Breakers 13A MCB B Char 1pl 277VAC UL508 1In Stock
Min.: 1
Mult.: 1

UM 13 A 277 VAC 42 VDC 1 Pole Handle - 25 C + 55 C Non-Illuminated
Altech Circuit Breakers 1BU3A MCB B CHar 1 pl 277V UL 508 1In Stock
Min.: 1
Mult.: 1

UM 3 A 277 VAC 42 VDC 1 Pole Handle - 25 C + 55 C Non-Illuminated
Altech Circuit Breakers 5A CRT BRKR CCHAR 277VAC UL508 1In Stock
Min.: 1
Mult.: 1

UM 15 A 277 VAC 42 VDC 1 Pole Handle - 25 C + 55 C Non-Illuminated
Altech Circuit Breakers 16A MCB CCHAR 1pl 277VAC UL508 1In Stock
Min.: 1
Mult.: 1

UM Circuit Breakers C-Trip 16 A 277 VAC 42 VDC 1 Pole Handle - 25 C + 55 C Non-Illuminated
Altech Circuit Breakers 2A MCB CCHAR 1pl 277VAC UL508 28In Stock
Min.: 1
Mult.: 1

UM 2 A 277 VAC 42 VDC 1 Pole Handle - 25 C + 55 C Non-Illuminated
Altech Circuit Breakers 5A MCB CCHAR 1pl 277VAC UL508 17In Stock
Min.: 1
Mult.: 1

UM Circuit Breakers C-Trip 5 A 277 VAC 42 VDC 1 Pole Handle - 25 C + 55 C Non-Illuminated
Altech Circuit Breakers 8A MCB CCHAR 1pl 277VAC UL508 1In Stock
Min.: 1
Mult.: 1

UM Circuit Breakers C-Trip 8 A 277 VAC 42 VDC 1 Pole Handle - 25 C + 55 C Non-Illuminated
Altech Circuit Breakers 15A D Characteristic UL 508 1 POLE 4In Stock
Min.: 1
Mult.: 1

UM Circuit Breakers D-Trip 15 A 277 VAC 42 VDC 1 Pole Handle - 25 C + 55 C Non-Illuminated
Altech Circuit Breakers 1A D Characteristic UL 508 1 POLE 4In Stock
Min.: 1
Mult.: 1

UM Circuit Breakers D-Trip 1 A 277 VAC 42 VDC 1 Pole Handle - 25 C + 55 C Non-Illuminated
Altech Circuit Breakers 2A D Characteristic UL 508 1 POLE 1In Stock
Min.: 1
Mult.: 1

UM Circuit Breakers D-Trip 2 A 277 VAC 42 VDC 1 Pole Handle - 25 C + 55 C Non-Illuminated
Altech Circuit Breakers 10A CRT BRKR ECHAR 277VAC UL508 5In Stock
Min.: 1
Mult.: 1

UM 10 A 277 VAC 42 VDC 1 Pole Handle - 25 C + 55 C Non-Illuminated
Altech Circuit Breakers 13A CRT BRKR ECHAR 277VAC UL508 5In Stock
Min.: 1
Mult.: 1

UM Circuit Breakers E-Trip 13 A 277 VAC 42 VDC 1 Pole Handle - 25 C + 55 C Non-Illuminated
Altech Circuit Breakers 20A G Characteristic UL 508 1 POLE 4In Stock
2Expected 7/13/2026
Min.: 1
Mult.: 1

UM Circuit Breakers G-Trip 20 A 277 VAC 42 VDC 1 Pole Handle - 25 C + 55 C Non-Illuminated
Altech Circuit Breakers 25A G Characteristic UL 508 1 POLE 1In Stock
Min.: 1
Mult.: 1

UM Circuit Breakers G-Trip 25 A 277 VAC 42 VDC 1 Pole Handle - 25 C + 55 C Non-Illuminated
Altech Circuit Breakers 30A G Characteristic UL 508 1 POLE 1In Stock
Min.: 1
Mult.: 1

UM Circuit Breakers G-Trip 30 A 277 VAC 24 VDC 1 Pole Handle - 25 C + 55 C Non-Illuminated
Altech Circuit Breakers 6A G Characteristic UL 508 1 POLE 10In Stock
Min.: 1
Mult.: 1

UM 6 A 277 VAC 42 VDC 1 Pole Handle - 25 C + 55 C Non-Illuminated
Altech Circuit Breakers 16A Z Characteristic UL 508 1 POLE 2In Stock
Min.: 1
Mult.: 1

UM 16 A 277 VAC 42 VDC 1 Pole Handle - 25 C + 55 C Non-Illuminated
Altech Circuit Breakers 15A CRT BRKR CCHAR 277VAC UL508 7In Stock
Min.: 1
Mult.: 1

UM Circuit Breakers C-Trip 15 A 277 VAC 80 VDC 2 Pole Handle - 25 C + 55 C Non-Illuminated
Altech Circuit Breakers 1A MCB CCHAR 1P+N 277VAC UL508 3In Stock
Min.: 1
Mult.: 1

UM 1 A 277 VAC 80 VDC 2 Pole Handle - 25 C + 55 C Non-Illuminated