MLX91220 Current Sensors

Melexis MLX91220 Current Sensors operate on a 5V voltage supply and provide high common-mode field rejection through differential sensing. They sense the current flowing through the lead frame of their SOIC package, minimizing the thermal losses encountered with more standard solutions. These 0A to 50A integrated Hall effect sensors feature dual overcurrent detection (OCD) on-chip with a separated output, reducing the need for external comparators for overcurrent protection. The all-in-one MLX91220 sensors offer an ideal balance of a small footprint, low impedance, high bandwidth, and isolation. Melexis MLX91220 Current Sensors provide high-speed sensing with a DC to 300kHz bandwidth and 2μs response time. Typical applications include AC and DC chargers, electric drives, DC-DC converters, solar, power supplies, and demand/load control.

Results: 39
Select Image Part # Mfr. Description Datasheet Availability Pricing (EUR) Filter the results in the table by unit price based on your quantity. Qty. RoHS ECAD Model Current Rating Sensor Type Response Time Frequency Range Operating Supply Voltage Output Type Qualification
Melexis Board Mount Current Sensors Gen2-InP-CurrentSensor-50AB.FSRatio-5V-3.55kVisolation Non-Stocked Lead-Time 12 Weeks
Min.: 3.000
Mult.: 3.000
Reel: 3.000

50 mA Current Sense 3 us 0 Hz to 300 kHz 5 V Ratiometric AEC-Q100
Melexis Board Mount Current Sensors Gen2-InP-CurrentSensor-50AB.FSFixed-5V-5.4kVisolation-OCD Non-Stocked Lead-Time 12 Weeks
Min.: 1.500
Mult.: 1.500
Reel: 1.500

50 mA Current Sense 3 us 0 Hz to 300 kHz 5 V Analog AEC-Q100
Melexis Board Mount Current Sensors Gen2-InP-CurrentSensor-17AB.FSFixed-5V-5.4kVisolation-OCDadjusted Non-Stocked Lead-Time 12 Weeks
Min.: 1.500
Mult.: 1.500
Reel: 1.500

17 mA Current Sense 3 us 0 Hz to 300 kHz 5 V Analog AEC-Q100
Melexis Board Mount Current Sensors Gen2-InP-CurrentSensor-25AB.FSRatio-5V-5.4kVisolation-OCD Non-Stocked Lead-Time 12 Weeks
Min.: 1
Mult.: 1
Reel: 1.500

25 mA Current Sense 3 us 0 Hz to 300 kHz 5 V Analog AEC-Q100
Melexis Board Mount Current Sensors Gen2-InP-CurrentSensor-75AB.FSRatio-5V-5.4kVisolation-OCD Non-Stocked Lead-Time 12 Weeks
Min.: 1.500
Mult.: 1.500
Reel: 1.500

75 mA Current Sense 3 us 0 Hz to 300 kHz 5 V Analog AEC-Q100
Melexis Board Mount Current Sensors Gen2-InP-CurrentSensor-50AU.FSFixed-5V-5.4kVisolation-OCD Non-Stocked Lead-Time 12 Weeks
Min.: 1.500
Mult.: 1.500
Reel: 1.500

50 mA
Melexis Board Mount Current Sensors Gen2-InP-CurrentSensor-50AU.FSFixed-5V-5.4kVisolation-OCD Non-Stocked Lead-Time 2 Weeks
Min.: 1
Mult.: 1

50 mA
Melexis Board Mount Current Sensors Gen2-InP-CurrentSensor-25AB.FSFixed-5V-3.55kVisolation Non-Stocked Lead-Time 12 Weeks
Min.: 1
Mult.: 1

25 mA AEC-Q100
Melexis Board Mount Current Sensors Gen2-InP-CurrentSensor-50AB.FSRatio-5V-3.55kVisolation Non-Stocked Lead-Time 12 Weeks
Min.: 1.040
Mult.: 80

50 mA AEC-Q100
Melexis Board Mount Current Sensors Gen2-InP-CurrentSensor-25AB.FSFixed-5V-5.4kVisolation-OCD Non-Stocked Lead-Time 12 Weeks
Min.: 1.053
Mult.: 39

25 mA AEC-Q100
Melexis Board Mount Current Sensors Gen2-InP-CurrentSensor-50AB.FSFixed-5V-5.4kVisolation-OCD Non-Stocked Lead-Time 12 Weeks
Min.: 1.014
Mult.: 39

50 mA AEC-Q100
Melexis Board Mount Current Sensors Gen2-InP-CurrentSensor-25AB.FSRatio-5V-5.4kVisolation-OCD Non-Stocked Lead-Time 12 Weeks
Min.: 1.014
Mult.: 39

25 mA AEC-Q100
Melexis Board Mount Current Sensors Gen2-InP-CurrentSensor-50AB.FSRatio-5V-5.4kVisolation-OCD Non-Stocked Lead-Time 12 Weeks
Min.: 1.014
Mult.: 39

50 mA AEC-Q100
Melexis Board Mount Current Sensors Gen2-InP-CurrentSensor-25AB.FSRatio-5V-3.55kVisolation Non-Stocked Lead-Time 12 Weeks
Min.: 1.040
Mult.: 80

25 mA AEC-Q100